Product Overview: This device complies with standard requirements of GB2099 - 2008 (Figure 29) , IEC60884 (Figure 29) , applicable for the test of mechanical strength of the lightest soft wire in the rewirable mobile socket.
Test principle: fix the free end of soft to the wall, the fixed point is of 750 mm height from the ground, grasp the specimen to make the soft in the state level, and then drop the sample to the concrete floor eight times. Each time after falling, on the fixed point turn the soft cable to a 45 ° angle. After the test, the sample should not be damaged in the standard sense; especially parts shall not be loose or fall off.